The purpose of this Standard is to minimize the risk of personal injury by providing minimum requirements for the design, construction, installation, inspection, and maintenance of the mechanical refrigeration systems and volatile direct refrigeration systems specified in Clauses 1.2.1 and 1.2.2. Note: This Standard does not directly address protection of property and preservation of the environment.
Application
Except as specified in Clause 1.2.3, this Standard applies to the design, construction, installation, inspection, and maintenance of every refrigeration system as provided for by the “Act” (as defined in Clause 3) and identified in this Standard.
This Standard applies to
a) all refrigeration systems installed subsequent to its adoption. This includes refrigeration systems installed in a new or existing premises. It also applies to all premises, including the machinery room if required, in which a refrigeration system is to be installed;
b) refrigeration systems that undergo a substitution of refrigerant in a premises defined in Item a); and
c) those parts of a refrigeration system that are replaced in, or added to, systems installed prior to its adoption.
Note: When adding or replacing parts [see Item c)], consideration should be given to the premises requirements of Item a).
This Standard does not apply to the following:
a) the use of water or air as a refrigerant;
b) bulk-storage gas tanks not permanently connected to a refrigeration system;
c) refrigeration systems installed on railroad cars, motor vehicles, motor-drawn vehicles, aircraft, or ships; and
d) refrigeration systems used for air conditioning in private residences.
Terminology In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Units of measurement The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only. A list of conversion factors is provided in Annex D. Pressure, unless otherwise stated, is expressed in kilopascals above atmospheric pressure, i.e., gauge pressure.
  1. Csa B52 Mechanical Refrigeration Code Ontario
  1. The CSA B52 Course is directed toward Designers, manufacturers, owners, users and persons charged with the responsibility for the safe operating practices, installation and maintenance of mechanical refrigeration systems in.
  2. The machinery room in which the plant is located must meet the latest CAN/CSA B52. Mechanical Refrigeration Code machinery room requirements.

Csa B52 Mechanical Refrigeration Code Ontario

Csa B52 Mechanical Refrigeration Code PdfCsa B52 Mechanical Refrigeration Code PdfCsa B52 Mechanical Refrigeration Code Pdf

Preface This is the second edition of CSA B52 HB, A practical handbook for implementing CSA B52-13, Mechanical refrigeration code. Downloadable PDF.